WSEAS Transactions on Systems and Control
Print ISSN: 1991-8763, E-ISSN: 2224-2856
Volume 21, 2026
Comparative Analysis of Harmonic Control Techniques in a Photovoltaic Microgrid with Simulation-Based Prediction
Authors: , , , ,
Search Articles
Abstract: This research presents a comparative analysis with stochastic validation of three control strategies for harmonic mitigation in a 120 V photovoltaic microgrid subject to variable climatic conditions. The conventional MPPT (Perturb and Observe) control, MPPT with a tuned double passive filter, and the Fuzzy Logic Controller (FLC) were compared. The results obtained from the MATLAB/Simulink simulation indicated that the conventional MPPT system does not comply with the IEEE 519-2014 standard, registering a voltage THD (Total harmonic distortion) of 13.19 % and a current THD of 22.81 %. With the incorporation of the passive filter, the voltage THD was reduced to 0.69% and the current THD to 0.03 % in steady state. Meanwhile, the FLC proved to be a robust and adaptable solution because it algorithmically mitigated harmonics with a THD within the regulatory limits (4.09 %) and a THDi of 4.41 %. Furthermore, it reduced the settling time to 0.028 s with an improvement in power transfer at a useful current of 59 A. Finally, the model prediction was validated with Monte Carlo simulations based on 672 records with irradiance and temperature input data and load harmonic measurements taken with a Fluke analyzer 435, obtaining a relative error of 5.00 %.
Keywords:
Active Power Filter, Harmonic Control Techniques, Harmonic Mitigation, MATLAB Simulation, Photovoltaic Microgrid, Power Quality
Pages: 581-589
DOI: 10.37394/23203.2026.21.50