<doi_batch xmlns="http://www.crossref.org/schema/4.4.0" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" version="4.4.0"><head><doi_batch_id>5447371a-eab8-4376-b31d-c38cf5b7fb60</doi_batch_id><timestamp>20241113062533320</timestamp><depositor><depositor_name>wseas:wseas</depositor_name><email_address>mdt@crossref.org</email_address></depositor><registrant>MDT Deposit</registrant></head><body><journal><journal_metadata language="en"><full_title>WSEAS TRANSACTIONS ON CIRCUITS AND SYSTEMS</full_title><issn media_type="electronic">2224-266X</issn><issn media_type="print">1109-2734</issn><archive_locations><archive name="Portico"/></archive_locations><doi_data><doi>10.37394/23201</doi><resource>http://wseas.org/wseas/cms.action?id=2861</resource></doi_data></journal_metadata><journal_issue><publication_date media_type="online"><month>2</month><day>9</day><year>2024</year></publication_date><publication_date media_type="print"><month>2</month><day>9</day><year>2024</year></publication_date><journal_volume><volume>23</volume><doi_data><doi>10.37394/23201.2024.23</doi><resource>https://wseas.com/journals/cas/2024.php</resource></doi_data></journal_volume></journal_issue><journal_article language="en"><titles><title>High Gradient Magnetic Fields Generated in Events on the 230 kV Electric Power Transmission Infrastructure: Human Exposure Analysis and Risk</title></titles><contributors><person_name sequence="first" contributor_role="author"><given_name>Fabian Ricardo</given_name><surname>Rojas</surname><affiliation>Enlaza-GEB, COLOMBIA</affiliation></person_name><person_name sequence="additional" contributor_role="author"><given_name>Gerardo</given_name><surname>Guerra</surname><affiliation>Enlaza-GEB, COLOMBIA</affiliation></person_name><person_name sequence="additional" contributor_role="author"><given_name>Sergio</given_name><surname>Rivera</surname><affiliation>Departamento de Ingeniería Eléctrica, Universidad Nacional de Colombia SEDE Bogotá, COLOMBIA</affiliation></person_name></contributors><jats:abstract xmlns:jats="http://www.ncbi.nlm.nih.gov/JATS1"><jats:p>This work presents a process for analyzing human exposure to high-gradient magnetic fields based on protection models for patients undergoing magnetic resonance examinations developed by the International Commission on Non-Ionizing Radiation Protection (ICNIRP). A series of events presented in the electrical energy transmission infrastructure is taken, with typical currents and front times, a case of extreme failure is added, and results are presented. Subsequently, with a classic lightning signal, compliance with the exposure to this type of field in the right-of-way strip of a transmission line is verified and validated in the event of a hypothetical atmospheric discharge impact event. Finally, a simulation is implemented with space discretization techniques, establishing the signal resulting from the magnetic field generated as a function of time. The exposure is evaluated using the presented model. Only in one of the analysis cases was it found that the perception threshold is exceeded at distances less than 0.6 cm, virtually a situation in which the worker has contact with the down conductor. With the results obtained and the cases analyzed, it is concluded that failures of this type do not generate significant exposure to high-gradient magnetic fields and do not exceed the determined perception thresholds.</jats:p></jats:abstract><publication_date media_type="online"><month>11</month><day>13</day><year>2024</year></publication_date><publication_date media_type="print"><month>11</month><day>13</day><year>2024</year></publication_date><pages><first_page>212</first_page><last_page>222</last_page></pages><publisher_item><item_number item_number_type="article_number">22</item_number></publisher_item><ai:program xmlns:ai="http://www.crossref.org/AccessIndicators.xsd" name="AccessIndicators"><ai:free_to_read start_date="2024-11-13"/><ai:license_ref applies_to="am" start_date="2024-11-13">https://wseas.com/journals/cas/2024/a445116-858.pdf</ai:license_ref></ai:program><archive_locations><archive name="Portico"/></archive_locations><doi_data><doi>10.37394/23201.2024.23.22</doi><resource>https://wseas.com/journals/cas/2024/a445116-858.pdf</resource></doi_data><citation_list><citation key="ref0"><doi>10.1109/iclp.2010.7845806</doi><unstructured_citation>International Electrotechnical Commission, "IEC 62305 - Protection against Lightning," IEC, Geneva, Switzerland, 2010, [Online]. https://webstore.iec.ch/publication/60559 (Accessed Date: October 14, 2024). </unstructured_citation></citation><citation key="ref1"><unstructured_citation>A. K. Gupta, N. G. Prakash, and T. R. Viswanath, "Human Exposure to Electromagnetic Fields: A Review of the Current Knowledge," IEEE Access, vol. 9, pp. 155653–155663, Nov. 2021. doi: 10.1109/ACCESS.2021.3115824. </unstructured_citation></citation><citation key="ref2"><doi>10.1201/9781003201052-10</doi><unstructured_citation>C. A. M. Pavan and M. J. S. Ferreira, "Effects of Electromagnetic Fields on Human Health," in Human Health Effects of Electromagnetic Fields, A. S. A. Al-Ali, Ed., International Conference on Electromagnetic Fields, 2021, pp. 1-15. doi: 10.1007/978-3-030-51938-2_1. </unstructured_citation></citation><citation key="ref3"><doi>10.1097/hp.0b013e3181aff9db</doi><unstructured_citation>ICNIRP, "Guidelines for Limiting Exposure to Time-Varying Electric, Magnetic, and Electromagnetic Fields (up to 300 GHz)," Health Physics, vol. 74, no. 4, pp. 494–521, Apr. 1998. doi: 10.1097/00004032- 199804000-00023. </unstructured_citation></citation><citation key="ref4"><doi>10.1097/00004032-200303000-00016</doi><unstructured_citation>ICNIRP, "Guidance On Determining Compliance Of Exposure To Pulsed And Complex Non-Sinusoidal Waveforms Below 100 kHz With ICNIRP Guidelines," Health Physics, vol. 85, no. 4, pp. 383–387, Oct. 2003. doi: 10.1097/01.HP.0000072980.35049.4F. </unstructured_citation></citation><citation key="ref5"><doi>10.1097/hp.0b013e3181f06c86</doi><unstructured_citation>ICNIRP, "Guidelines for Limiting Exposure to Time-Varying Electric and Magnetic Fields (1 Hz to 100 kHz)," Health Physics, vol. 99, no. 6, pp. 818–836, Dec. 2010. doi: 10.1097/HP.0b013e3181f06c86. </unstructured_citation></citation><citation key="ref6"><doi>10.1115/mts2013-0321</doi><unstructured_citation>National Fire Protection Association, "NFPA 780: Standard for the Installation of Lightning Protection Systems," NFPA, Quincy, MA, USA, 2017, [Online]. https://www.nfpa.org/codes-and-standards/allcodes-and-standards/list-of-codes-andstandards (Accessed Date: October 14, 2024). </unstructured_citation></citation><citation key="ref7"><doi>10.1109/iclp.2010.7845793</doi><unstructured_citation>Z. A. Tamus, B. Novak, S. V. Szabo, I. Kiss, and I. Berta, "Can the Near Field of Lightning Impulse in Down Conductors Cause Harmful Health Effects?" in 30th International Conference on Lightning Protection (ICLP), Cagliari, Italy, 2010, pp. 1–4. doi: 10.1109/ICLP.2010.7845793. </unstructured_citation></citation><citation key="ref8"><doi>10.1097/00004032-200408000-00008</doi><unstructured_citation>ICNIRP, "Medical Magnetic Resonance (MR) Procedures: Protection of Patients," Health Physics, vol. 87, no. 2, pp. 197–216, Aug. 2004, [Online]. http://www.ncbi.nlm.nih.gov/pubmed/152572 20 (Accessed Date: October 14, 2024). </unstructured_citation></citation><citation key="ref9"><unstructured_citation>F. G. Shellock, Magnetic Resonance Procedures: Health Effects and Safety, Boca Raton, FL: CRC Press, 2000. doi: 10.1201/9781420040004. </unstructured_citation></citation><citation key="ref10"><doi>10.1109/iclp.2010.7845806</doi><unstructured_citation>International Electrotechnical Commission, "IEC 62305 - Protection against Lightning," IEC, Geneva, Switzerland, 2010, [Online]. https://webstore.iec.ch/publication/60559 (Accessed Date: October 14, 2024). </unstructured_citation></citation><citation key="ref11"><unstructured_citation>R. P. O. de Araújo, M. Z. Lima, and A. A. Guiot, "Assessment of Lightning Protection System Design Based on the IEC 62305-3 Standard," IEEE Latin America Transactions, vol. 14, no. 4, pp. 1778–1783, Apr. 2016. doi: 10.1109/TLA.2016.7452461. </unstructured_citation></citation><citation key="ref12"><doi>10.3390/en13040957</doi><unstructured_citation>C. Baron, A. S. Al-Sumaiti, and S. Rivera, "Impact of Energy Storage Useful Life on Intelligent Microgrid Scheduling," Energies, vol. 13, no. 4, p. 957, 2020. doi: 10.3390/en13040957.</unstructured_citation></citation></citation_list></journal_article></journal></body></doi_batch>