<?xml version='1.0' encoding='UTF-8'?>
<doi_batch version="5.4.0" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.crossref.org/schema/5.4.0" xsi:schemaLocation="http://www.crossref.org/schema/5.4.0 https://www.crossref.org/schemas/crossref5.4.0.xsd" xmlns:jats="http://www.ncbi.nlm.nih.gov/JATS1" xmlns:fr="http://www.crossref.org/fundref.xsd" xmlns:ai="http://www.crossref.org/AccessIndicators.xsd" xmlns:rel="http://www.crossref.org/relations.xsd" xmlns:mml="http://www.w3.org/1998/Math/MathML">
  <head>
    <doi_batch_id>NONE</doi_batch_id>
    <timestamp>20260910085900071</timestamp>
    <depositor>
      <depositor_name>wseas/wseas</depositor_name>
      <email_address>content-registration-form@crossref.org</email_address>
    </depositor>
    <registrant>content-registration-form</registrant>
  </head>
  <body>
    <journal>
      <journal_metadata>
        <full_title>WSEAS TRANSACTIONS ON BIOLOGY AND BIOMEDICINE</full_title>
        <issn media_type="print">1109-9518</issn>
        <issn media_type="electronic">2224-2902</issn>
      </journal_metadata>
      <journal_issue>
        <publication_date media_type="print">
          <month>01</month>
          <day>07</day>
          <year>2025</year>
        </publication_date>
        <publication_date media_type="online">
          <month>01</month>
          <day>07</day>
          <year>2025</year>
        </publication_date>
        <journal_volume>
          <volume>22</volume>
        </journal_volume>
      </journal_issue>
      <journal_article>
        <titles>
          <title>Comparison of Magnetic Field Characteristics among 3 Tesla MRI Scanners: An Experimental Measurement Study</title>
        </titles>
        <contributors>
          <person_name sequence="first" contributor_role="author">
            <given_name>Francesco</given_name>
            <surname>Girardello</surname>
            <affiliations>
              <institution>
                <institution_name>CNR, Institute of Clinical Physiology 56124 Pisa, ITALY</institution_name>
              </institution>
            </affiliations>
          </person_name>
          <person_name sequence="additional" contributor_role="author">
            <given_name>Maria Antonietta</given_name>
            <surname>D’avanzo</surname>
            <affiliations>
              <institution>
                <institution_name>INAIL, Department of Occupational and Environmental Medicine Via Fontana Candida 1, 00078 Rome, ITALY</institution_name>
              </institution>
            </affiliations>
          </person_name>
          <person_name sequence="additional" contributor_role="author">
            <given_name>Massimo</given_name>
            <surname>Mattozzi</surname>
            <affiliations>
              <institution>
                <institution_name>INAIL, Department of Occupational and Environmental Medicine Via Fontana Candida 1, 00078 Rome, ITALY</institution_name>
              </institution>
            </affiliations>
          </person_name>
          <person_name sequence="additional" contributor_role="author">
            <given_name>Victorian Michele</given_name>
            <surname>Ferro</surname>
            <affiliations>
              <institution>
                <institution_name>Dipartimento di Scienze Biomediche, Odontoiatriche e delle Immagini Morfologiche e Funzionali, Università degli Studi di Messina, 98125 Messina, ITALY</institution_name>
              </institution>
            </affiliations>
          </person_name>
          <person_name sequence="additional" contributor_role="author">
            <given_name>Giuseppe</given_name>
            <surname>Acri</surname>
            <affiliations>
              <institution>
                <institution_name>Dipartimento di Scienze Biomediche, Odontoiatriche e delle Immagini Morfologiche e Funzionali, Università degli Studi di Messina, 98125 Messina, ITALY</institution_name>
              </institution>
            </affiliations>
          </person_name>
          <person_name sequence="additional" contributor_role="author">
            <given_name>Valentina</given_name>
            <surname>Hartwig</surname>
            <affiliations>
              <institution>
                <institution_name>CNR, Institute of Clinical Physiology 56124 Pisa, ITALY</institution_name>
              </institution>
            </affiliations>
          </person_name>
        </contributors>
        <jats:abstract xml:lang="eng">
          <jats:p>Magnetic resonance imaging (MRI) scanners have advanced significantly, with a growing use of high-field 3 T systems. This evolution gives rise to safety concerns for healthcare personnel working in proximity to MRI equipment. While manufacturers provide theoretical Gauss line projections, these are typically derived under ideal open-environment conditions and may not reflect real-world installations. For this reason, identical MRI models can produce markedly different fringe field distributions depending on shielding and room configurations. The present study proposes an experimental methodology for the mapping of the fringe magnetic field in the vicinity of three 3 T MRI scanners. Field measurements were interpolated to generate three-dimensional magnetic field maps. A comparative analysis was conducted, which revealed notable differences among the scanners. These differences serve to highlight the influence of site-specific factors on magnetic field propagation.</jats:p>
        </jats:abstract>
        <publication_date media_type="print">
          <month>12</month>
          <day>17</day>
          <year>2025</year>
        </publication_date>
        <publication_date media_type="online">
          <month>12</month>
          <day>17</day>
          <year>2025</year>
        </publication_date>
        <pages>
          <first_page>490</first_page>
        </pages>
        <publisher_item>
          <item_number item_number_type="article_number">45</item_number>
        </publisher_item>
        <ai:program name="AccessIndicators">
          <ai:license_ref>https://creativecommons.org/licenses/by/4.0/deed.en_US</ai:license_ref>
        </ai:program>
        <doi_data>
          <doi>10.37394/23208.2025.22.45</doi>
          <resource>https://wseas.com/journals/bab/2025/a905108-034(2025).pdf</resource>
        </doi_data>
        <citation_list>
          <citation key="ref0">
            <unstructured_citation>Mukhatov A, Le T, Pham TT, Do TD. A comprehensive review on magnetic imaging techniques for biomedical applications. Nano Sel. 2023;4(3):213–30. https://doi.org/10.1002/nano.202200219. DOI: 10.1002/nano.202200219</unstructured_citation>
          </citation>
          <citation key="ref1">
            <unstructured_citation>Hartwig V, Romeo S, Zeni O. Occupational exposure to electromagnetic fields in magnetic resonance environment: basic aspects and review of exposure assessment approaches. Med Biol Eng Comput. 2018;56(4):531–45. https://doi.org/10.1007/s11517-021-02435-6. DOI: 10.1007/s11517-017-1779-7</unstructured_citation>
          </citation>
          <citation key="ref2">
            <unstructured_citation>Hartwig V, Virgili G, Mattei F, Biagini C, Romeo S, Zeni O, et al. Occupational exposure to electromagnetic fields in magnetic resonance environment: an update on regulation, exposure assessment techniques, health risk evaluation, and surveillance. Med Biol Eng Comput. 2022;60(2):297–320. https://doi.org/10.1007/s11517-021-02435-6. DOI: 10.1007/s11517-021-02435-6</unstructured_citation>
          </citation>
          <citation key="ref3">
            <unstructured_citation>Acri G, Inferrera P, Denaro L, Sansotta C, Ruello E, Anfuso C, et al. dB/dt evaluation in MRI sites: Is ICNIRP threshold limit (for workers) exceeded? Int J Environ Res Public Health. 2018;15(7):1–13. https://doi.org/10.3390/ijerph15071298. DOI: 10.3390/ijerph15071298</unstructured_citation>
          </citation>
          <citation key="ref4">
            <unstructured_citation>McRobbie DW. Essentials of MRI safety. Hoboken, New Jersey, US: Wiley-Blackwell; 2020. 392 p.</unstructured_citation>
          </citation>
          <citation key="ref5">
            <unstructured_citation>Zanotti G, Ligabue G, Korpinen L, Gobba F. Subjective symptoms in Magnetic Resonance Imaging operators: prevalence, short-term evolution and possible related factors. Med del Lav. 2016;107(4):263–70. https://doi.org/10.23749/mdl.v107i4.5240.</unstructured_citation>
          </citation>
          <citation key="ref6">
            <unstructured_citation>Wilén J, Vocht F De. Health complaints among nurses working near MRI scanners — A descriptive pilot study. Eur J Radiol. 2011;80(2):510–3. https://doi.org/10.1016/j.ejrad.2010.09.021. DOI: 10.1016/j.ejrad.2010.09.021</unstructured_citation>
          </citation>
          <citation key="ref7">
            <unstructured_citation>Hartwig V, Biagini C, De Marchi D, Flori A, Gabellieri C, Virgili G, et al. The Procedure for Quantitative Characterization and Analysis of Magnetic Fields in Magnetic Resonance Sites for Protection of Workers: A Pilot Study. Ann Work Expo Heal. 2019;63(3):1–9. https://doi.org/10.1093/annweh/wxz002. DOI: 10.1093/annweh/wxz002</unstructured_citation>
          </citation>
          <citation key="ref8">
            <unstructured_citation>Hartwig V, Cianfaglione M, Campanella F, D’Avanzo MA, Sansotta C, Acri G. Assessment of Exposure to Spatially Varying Magnetic Fields in MRI Environments: Modeling Analysis for Simulation Tools. IEEE Access. 2024;12(January):11492–9. https://doi.org/10.1109/ACCESS.2024.335519 1. DOI: 10.1109/ACCESS.2024.3355191</unstructured_citation>
          </citation>
          <citation key="ref9">
            <unstructured_citation>Capstick M, McRobbie D, Hand JW, Christ A, Kuhn S, Hansson K, et al. An Investigation into Occupational Exposure to Electromagnetic Fields for Personnel Working With and Around Medical Magnetic Resonance Imaging Equipment. EU COMMISSION Study on MRI (Project VT/2007/017), 287pp., April 4, 2008.</unstructured_citation>
          </citation>
          <citation key="ref10">
            <unstructured_citation>Dodge Y. The Concise Encyclopedia of Statistics. Springer New York; 2008.</unstructured_citation>
          </citation>
          <citation key="ref11">
            <unstructured_citation>White DR, Saunders P. The propagation of uncertainty with calibration equations. Meas Sci Technol. 2007;18(7):2157–69. https://doi.org/10.1088/0957-0233/18/7/047. DOI: 10.1088/0957-0233/18/7/047</unstructured_citation>
          </citation>
          <citation key="ref12">
            <unstructured_citation>OHCOW. Anthropometric Calculator (Male), [Online]. https://www.ohcow.on.ca/resources/appstools-calculators/anthropometric-calculator2024/en/male/ (Accessed Date: October 10, 2024).</unstructured_citation>
          </citation>
          <citation key="ref13">
            <unstructured_citation>Greenberg TD, Hoff MN, Gilk TB, Jackson EF, Kanal E, McKinney AM, et al. ACR guidance document on MR safe practices: Updates and critical information 2019. J Magn Reson Imaging. 2020;51(2):331–8. https://doi.org/10.1002/jmri.26880. DOI: 10.1002/jmri.26880</unstructured_citation>
          </citation>
          <citation key="ref14">
            <unstructured_citation>Hong YS, Aisyah S, Nordin M, Mustajfa M, Kechik A, Khalis M, et al. Safety Evaluation of MRI Magnetic Field Leakage from Different Configurations. J Mater Sci Radiat. 2025;1(1):7–14.</unstructured_citation>
          </citation>
        </citation_list>
      </journal_article>
    </journal>
  </body>
</doi_batch>